Skip to main content

Sick Building/House Syndrome

  • Chapter
  • First Online:

Abstract

Sick building syndrome (SBS) began to be reported mainly as a problem for office buildings, but home environments also may have the same problem. It is difficult to estimate accurately the prevalence of home SBS because widely accepted diagnostic criteria have not been established. However, the estimated prevalence of home SBS based on epidemiological studies seems to vary from a few to 10% or more. Causes and risks of home SBS include various environmental, personal, and social factors. Main environmental causal factors are aldehydes, volatile organic compounds (VOCs), dampness, and mold, although home airborne fungi levels measured quantitatively cannot affect SBS symptoms. Additionally, female, history of allergy or atopy, rental house, work stress, and unemployment can also pose as potential risk factors for home SBS. To avoid development of SBS in dwellings, construction materials, paintings, and furniture with low chemical emission must be used. Also, to reduce indoor chemical levels, dampness, and mold, home ventilation systems must be used properly and adequately.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   84.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD   159.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

References

  1. Kreiss K. The sick building syndrome in office buildings—a breath of fresh air. N Engl J Med. 1993;328(12):877–8. https://doi.org/10.1056/nejm199303253281210.

    Article  CAS  PubMed  Google Scholar 

  2. Redlich CA, Sparer J, Cullen MR. Sick-building syndrome. Lancet. 1997;349(9057):1013–6. https://doi.org/10.1016/s0140-6736(96)07220-0.

    Article  CAS  PubMed  Google Scholar 

  3. Engvall K, Norrby C, Bandel J, Hult M, Norback D. Development of a multiple regression model to identify multi-family residential buildings with a high prevalence of sick building syndrome (SBS). Indoor Air. 2000;10(2):101–10.

    Article  CAS  Google Scholar 

  4. Ohm M, Juto JE, Andersson K, Bodin L. Nasal histamine provocation of tenants in a sick-building residential area. Am J Rhinol. 1997;11(2):167–75.

    Article  CAS  Google Scholar 

  5. Miyata N, Nanba T, Nishimoto H. Sick house syndrome. J Ther. 1997;79(11):2498–9. (in Japanese).

    Google Scholar 

  6. Bradford Lyles W, Greve KW, Bauer RM, Ware MR, Schramke CJ, Crouch J, et al. Sick building syndrome. South Med J. 1991;84(1):65–76.

    Article  Google Scholar 

  7. Burge PS. Sick building syndrome. Occup Environ Med. 2004;61(2):185–90.

    Article  CAS  Google Scholar 

  8. Andersson K. Epidemiological approach to indoor air problems. Indoor Air. 1998;8(S4):32–9. https://doi.org/10.1111/j.1600-0668.1998.tb00005.x.

    Article  Google Scholar 

  9. Engvall K, Norrby C, Sandstedt E. The Stockholm Indoor Environment Questionnaire: a sociologically based tool for the assessment of indoor environment and health in dwellings. Indoor Air. 2004;14(1):24–33.

    Article  CAS  Google Scholar 

  10. Sahlberg B, Wieslander G, Norback D. Sick building syndrome in relation to domestic exposure in Sweden—a cohort study from 1991 to 2001. Scandinavian Journal of Public Health. 2010;38(3):232–8. https://doi.org/10.1177/1403494809350517.

    Article  CAS  PubMed  Google Scholar 

  11. Hodgson M, Levin H, Wolkoff P. Volatile organic compounds and indoor air. J Allergy Clin Immunol. 1994;94(2 Pt 2):296–303.

    Article  CAS  Google Scholar 

  12. Takigawa T, Wang BL, Saijo Y, Morimoto K, Nakayama K, Tanaka M, et al. Relationship between indoor chemical concentrations and subjective symptoms associated with sick building syndrome in newly built houses in Japan. Int Arch Occup Environ Health. 2010;83(2):225–35. https://doi.org/10.1007/s00420-009-0475-9.

    Article  CAS  Google Scholar 

  13. Takeda M, Saijo Y, Yuasa M, Kanazawa A, Araki A, Kishi R. Relationship between sick building syndrome and indoor environmental factors in newly built Japanese dwellings. Int Arch Occup Environ Health. 2009;82(5):583–93. https://doi.org/10.1007/s00420-009-0395-8.

    Article  CAS  Google Scholar 

  14. Takigawa T, Saijo Y, Morimoto K, Nakayama K, Shibata E, Tanaka M, et al. A longitudinal study of aldehydes and volatile organic compounds associated with subjective symptoms related to sick building syndrome in new dwellings in Japan. Sci Total Environ. 2012;417-418:61–7. https://doi.org/10.1016/j.scitotenv.2011.12.060.

    Article  CAS  PubMed  Google Scholar 

  15. Saijo Y, Kishi R, Sata F, Katakura Y, Urashima Y, Hatakeyama A, et al. Symptoms in relation to chemicals and dampness in newly built dwellings. Int Arch Occup Environ Health. 2004;77(7):461–70. https://doi.org/10.1007/s00420-004-0535-0.

    Article  CAS  Google Scholar 

  16. Osawa H, Ikeda K, Hayashi M, Kuwabara Y, Manabe J, Nakabayashi Y. Present status of the indoor air chemical pollution in Japanese houses based on the nationwide field study in 2000. J Environ Eng. 2003;68(566):65–71. (in Japanese, English abstract). https://doi.org/10.3130/aije.68.65_1.

    Article  Google Scholar 

  17. MHLW. Committee on sick house syndrome: indoor air pollution progress report no. 3-summary on the discussions at the 6th and 7th meetings-30 June 2017. 2001. http://www.nihs.go.jp/mhlw/chemical/situnai/kentoukai/rep-eng3.pdf.

  18. WHO. WHO guidelines for indoor air quality: selected pollutants. 2010. Geneva: World Health Organization.

    Google Scholar 

  19. Uchiyama S, Tomizawa T, Tokoro A, Aoki M, Hishiki M, Yamada T, et al. Gaseous chemical compounds in indoor and outdoor air of 602 houses throughout Japan in winter and summer. Environ Res. 2015;137:364–72. https://doi.org/10.1016/j.envres.2014.12.005.

    Article  CAS  PubMed  Google Scholar 

  20. German Committee on Indoor Guide Values. Guide values for the concentration of specific substances in indoor air. The Umweltbundesamt, Dessau-Roßlau. 2010. https://www.umweltbundesamt.de/sites/default/files/medien/4031/bilder/dateien/0_ausschuss_fur-innenraumrichtwerte_empfehlungen_und_richtwerte_20190128_en_003.pdf.

  21. Kanazawa A, Saito I, Araki A, Takeda M, Ma M, Saijo Y, et al. Association between indoor exposure to semi-volatile organic compounds and building-related symptoms among the occupants of residential dwellings. Indoor Air. 2010;20(1):72–84. https://doi.org/10.1111/j.1600-0668.2009.00629.x.

    Article  CAS  Google Scholar 

  22. Bergh C, Magnus Aberg K, Svartengren M, Emenius G, Ostman C. Organophosphate and phthalate esters in indoor air: a comparison between multi-storey buildings with high and low prevalence of sick building symptoms. Journal of Environmental Monitoring. 2011;13(7):2001–9. https://doi.org/10.1039/c1em10152h.

    Article  CAS  PubMed  Google Scholar 

  23. Jaakkola JJ, Knight TL. The role of exposure to phthalates from polyvinyl chloride products in the development of asthma and allergies: a systematic review and meta-analysis. Environ Health Perspect. 2008;116(7):845–53. https://doi.org/10.1289/ehp.10846.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  24. Bornehag CG, Sundell J, Weschler CJ, Sigsgaard T, Lundgren B, Hasselgren M, et al. The association between asthma and allergic symptoms in children and phthalates in house dust: a nested case-control study. Environ Health Perspect. 2004;112(14):1393–7.

    Article  CAS  Google Scholar 

  25. Kolarik B, Naydenov K, Larsson M, Bornehag CG, Sundell J. The association between phthalates in dust and allergic diseases among Bulgarian children. Environ Health Perspect. 2008;116(1):98–103. https://doi.org/10.1289/ehp.10498.

    Article  CAS  PubMed  Google Scholar 

  26. Ait Bamai Y, Shibata E, Saito I, Araki A, Kanazawa A, Morimoto K, et al. Exposure to house dust phthalates in relation to asthma and allergies in both children and adults. Sci Total Environ. 2014;485-486:153–63. https://doi.org/10.1016/j.scitotenv.2014.03.059.

    Article  CAS  PubMed  Google Scholar 

  27. Wieslander G, Norback D, Nordstrom K, Walinder R, Venge P. Nasal and ocular symptoms, tear film stability and biomarkers in nasal lavage, in relation to building-dampness and building design in hospitals. Int Arch Occup Environ Health. 1999;72(7):451–61.

    Article  CAS  Google Scholar 

  28. Norback D, Wieslander G, Nordstrom K, Walinder R. Asthma symptoms in relation to measured building dampness in upper concrete floor construction, and 2-ethyl-1-hexanol in indoor air. Int J Tuberculosis and lung disease. 2000;4(11):1016–25.

    CAS  Google Scholar 

  29. Kamijima M, Shibata E, Sakai K, Ohno H, Ishihara S, Yamada T, et al. [Indoor air pollution due to 2-ethyl-1-hexanol airborne concentrations, emission sources and subjective symptoms in classroom users]. [Nihon Koshu Eisei Zasshi] Japanese Journal of Public Health. 2005;52(12):1021–31. (in Japanese, English abstract).

    Google Scholar 

  30. Mendell MJ, Kumagai K. Observation-based metrics for residential dampness and mold with dose-response relationships to health: a review. Indoor Air. 2016. https://doi.org/10.1111/ina.12342.

    Article  Google Scholar 

  31. Engvall K, Norrby C, Norback D. Sick building syndrome in relation to building dampness in multi-family residential buildings in Stockholm. Int Arch Occup Environ Health. 2001;74(4):270–8.

    Article  CAS  Google Scholar 

  32. Saijo Y, Nakagi Y, Ito T, Sugioka Y, Endo H, Yoshida T. Relation of dampness to sick building syndrome in Japanese public apartment houses. Environ Health Prev Med. 2009;14(1):26–35. https://doi.org/10.1007/s12199-008-0052-y.

    Article  Google Scholar 

  33. Lu C, Deng Q, Li Y, Sundell J, Norback D. Outdoor air pollution, meteorological conditions and indoor factors in dwellings in relation to sick building syndrome (SBS) among adults in China. Science Total Environ. 2016;560-561:186–96. https://doi.org/10.1016/j.scitotenv.2016.04.033.

    Article  CAS  Google Scholar 

  34. Saijo Y, Nakagi Y, Ito T, Sugioka Y, Endo H, Yoshida T. Dampness, food habits, and sick building syndrome symptoms in elementary school pupils. Environ Health Prev Med. 2010;15(5):276–84. https://doi.org/10.1007/s12199-010-0139-0.

    Article  PubMed  PubMed Central  Google Scholar 

  35. Takaoka M, Suzuki K, Norback D. Sick building syndrome among junior high school students in japan in relation to the home and school environment. Global J Health Sci. 2015;8(2):165–77. https://doi.org/10.5539/gjhs.v8n2p165.

    Article  Google Scholar 

  36. Kishi R, Saijo Y, Kanazawa A, Tanaka M, Yoshimura T, Chikara H, et al. Regional differences in residential environments and the association of dwellings and residential factors with the sick house syndrome: a nationwide cross-sectional questionnaire study in Japan. Indoor Air. 2009;19(3):243–54. https://doi.org/10.1111/j.1600-0668.2009.00589.x.

    Article  CAS  Google Scholar 

  37. Wessen B, Schoeps KO. Microbial volatile organic compounds—what substances can be found in sick buildings? Analyst. 1996;121(9):1203–5.

    Article  CAS  Google Scholar 

  38. Andersson MA, Nikulin M, Koljalg U, Andersson MC, Rainey F, Reijula K, et al. Bacteria, molds, and toxins in water-damaged building materials. Appl Environ Microbiol. 1997;63(2):387–93.

    CAS  PubMed  PubMed Central  Google Scholar 

  39. Rylander R, Lin RH. (1→3)-beta-D-glucan—relationship to indoor air-related symptoms, allergy and asthma. Toxicology. 2000;152(1-3):47–52.

    Article  CAS  Google Scholar 

  40. Saijo Y, Kanazawa A, Araki A, Morimoto K, Nakayama K, Takigawa T, et al. Relationships between mite allergen levels, mold concentrations, and sick building syndrome symptoms in newly built dwellings in Japan. Indoor Air. 2011;21(3):253–63. https://doi.org/10.1111/j.1600-0668.2010.00698.x.

    Article  CAS  Google Scholar 

  41. Sahlberg B, Gunnbjornsdottir M, Soon A, Jogi R, Gislason T, Wieslander G, et al. Airborne molds and bacteria, microbial volatile organic compounds (MVOC), plasticizers and formaldehyde in dwellings in three North European cities in relation to sick building syndrome (SBS). Science Total Environ. 2013;444:433–40. https://doi.org/10.1016/j.scitotenv.2012.10.114.

    Article  CAS  Google Scholar 

  42. Lee T, Grinshpun SA, Martuzevicius D, Adhikari A, Crawford CM, Luo J, et al. Relationship between indoor and outdoor bio-aerosols collected with a button inhalable aerosol sampler in urban homes. Indoor Air. 2006;16(1):37–47. https://doi.org/10.1111/j.1600-0668.2005.00396.x.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  43. Sakai K, Tsubouchi H, Mitani K. Airborne concentrations of fungal and indoor air pollutants in dwellings in Nagoya, Japan. Nippon Koshu Eisei Zasshi. 2003;50(10):1017–29. (in Japanese).

    CAS  PubMed  Google Scholar 

  44. Shelton BG, Kirkland KH, Flanders WD, Morris GK. Profiles of airborne fungi in buildings and outdoor environments in the United States. Appl Environ Microbiol. 2002;68(4):1743–53.

    Article  CAS  Google Scholar 

  45. Takahashi T. Airborne fungal colony-forming units in outdoor and indoor environments in Yokohama, Japan. Mycopathologia. 1997;139(1):23–33.

    Article  CAS  Google Scholar 

  46. Heederik D, von Mutius E. Does diversity of environmental microbial exposure matter for the occurrence of allergy and asthma? J Allergy Clin Immunol. 2012;130(1):44–50. https://doi.org/10.1016/j.jaci.2012.01.067.

    Article  PubMed  Google Scholar 

  47. Araki A, Kawai T, Eitaki Y, Kanazawa A, Morimoto K, Nakayama K, et al. Relationship between selected indoor volatile organic compounds, so-called microbial VOC, and the prevalence of mucous membrane symptoms in single family homes. Sci Total Environ. 2010;408(10):2208–15. https://doi.org/10.1016/j.scitotenv.2010.02.012.

    Article  CAS  Google Scholar 

  48. Norback D, Hashim JH, Markowicz P, Cai GH, Hashim Z, Ali F, et al. Endotoxin, ergosterol, muramic acid and fungal DNA in dust from schools in Johor Bahru, Malaysia—Associations with rhinitis and sick building syndrome (SBS) in junior high school students. Sci Total Environ. 2016;545-546:95–103. https://doi.org/10.1016/j.scitotenv.2015.12.072.

    Article  CAS  PubMed  Google Scholar 

  49. Zhang X, Zhao Z, Nordquist T, Larsson L, Sebastian A, Norback D. A longitudinal study of sick building syndrome among pupils in relation to microbial components in dust in schools in China. Sci Total Environ. 2011;409(24):5253–9. https://doi.org/10.1016/j.scitotenv.2011.08.059.

    Article  CAS  Google Scholar 

  50. Kim H, Bernstein JA. Air pollution and allergic disease. Curr Allergy Asthma Rep. 2009;9(2):128–33.

    Article  CAS  Google Scholar 

  51. WHO. WHO guidelines for indoor air quality, dampness and mould. 2009. Geneva: World Health Organization. http://www.ncbi.nlm.nih.gov/books/NBK143941/pdf/TOC.pdf.

  52. Engvall K, Norrby C, Norback D. Ocular, nasal, dermal and respiratory symptoms in relation to heating, ventilation, energy conservation, and reconstruction of older multi-family houses. Indoor Air. 2003;13(3):206–11.

    Article  CAS  Google Scholar 

  53. Mizoue T, Reijula K, Andersson K. Environmental tobacco smoke exposure and overtime work as risk factors for sick building syndrome in Japan. Am J Epidemiol. 2001;154(9):803–8.

    Article  CAS  Google Scholar 

  54. Li L, Adamkiewicz G, Zhang Y, Spengler JD, Qu F, Sundell J. Effect of traffic exposure on sick building syndrome symptoms among parents/grandparents of preschool children in Beijing, China. PLoS One. 2015;10(6):e0128767. https://doi.org/10.1371/journal.pone.0128767.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  55. Nozaki A, Narita Y, Nishina H, Ichijyo Y, Yamashita Y. Study on the indoor air pollution caused by unvented kerosene fired space heater. Indoor Eniviron. 2015;18(1):33–44. (in Japanese, English abstract). https://doi.org/10.7879/siej.18.33.

    Article  Google Scholar 

  56. Carteret M, Pauwels JF, Hanoune B. Emission factors of gaseous pollutants from recent kerosene space heaters and fuels available in France in 2010. Indoor Air. 2012;22(4):299–308. https://doi.org/10.1111/j.1600-0668.2011.00763.x.

    Article  CAS  PubMed  Google Scholar 

  57. Engvall K, Hult M, Corner R, Lampa E, Norback D, Emenius G. A new multiple regression model to identify multi-family houses with a high prevalence of sick building symptoms “SBS”, within the healthy sustainable house study in Stockholm (3H). Int Arch Occup Environ Health. 2010;83(1):85–94. https://doi.org/10.1007/s00420-009-0447-0.

    Article  PubMed  Google Scholar 

  58. Brasche S, Bullinger M, Morfeld M, Gebhardt HJ, Bischof W. Why do women suffer from sick building syndrome more often than men?--subjective higher sensitivity versus objective causes. Indoor Air. 2001;11(4):217–22.

    Article  CAS  Google Scholar 

  59. Shusterman D, Murphy MA, Balmes J. Differences in nasal irritant sensitivity by age, gender, and allergic rhinitis status. Int Arch Occup Environ Health. 2003;76(8):577–83. https://doi.org/10.1007/s00420-003-0459-0.

    Article  PubMed  Google Scholar 

  60. Sahlberg B, Mi YH, Norback D. Indoor environment in dwellings, asthma, allergies, and sick building syndrome in the Swedish population: a longitudinal cohort study from 1989 to 1997. Int Arch Occup Environ Health. 2009;82(10):1211–8. https://doi.org/10.1007/s00420-009-0444-3.

    Article  CAS  PubMed  Google Scholar 

  61. Norback D, Edling C. Environmental, occupational, and personal factors related to the prevalence of sick building syndrome in the general population. Br J Ind Med. 1991;48(7):451–62.

    CAS  PubMed  PubMed Central  Google Scholar 

  62. Barmark M. Social determinants of the sick building syndrome: exploring the interrelated effects of social position and psychosocial situation. Int J Environ Health Res. 2015;25(5):490–507. https://doi.org/10.1080/09603123.2014.979776.

    Article  PubMed  Google Scholar 

  63. Runeson-Broberg R, Norback D. Sick building syndrome (SBS) and sick house syndrome (SHS) in relation to psychosocial stress at work in the Swedish workforce. Int Arch Occup Environ Health. 2013;86(8):915–22. https://doi.org/10.1007/s00420-012-0827-8.

    Article  PubMed  Google Scholar 

  64. Wang BL, Takigawa T, Yamasaki Y, Sakano N, Wang DH, Ogino K. Symptom definitions for SBS (sick building syndrome) in residential dwellings. Int J Hyg Environ Health. 2008;211(1-2):114–20. https://doi.org/10.1016/j.ijheh.2007.03.004.

    Article  PubMed  Google Scholar 

  65. Ishibashi M, Tonori H, Miki T, Miyajima E, Kudo Y, Tsunoda M, et al. Classification of patients complaining of sick house syndrome and/or multiple chemical sensitivity. Tohoku J Exp Med. 2007;211(3):223–33.

    Article  Google Scholar 

  66. Genuis SJ. Chemical sensitivity: pathophysiology or pathopsychology? Clin Ther. 2013;35(5):572–7. https://doi.org/10.1016/j.clinthera.2013.04.003.

    Article  CAS  PubMed  Google Scholar 

  67. Kobayashi S, Takeuchi S, Kojima H, Takahashi T, Jin K, Akitsu H, et al. Indoor air pollution in a newly constructed elementary school caused by 1-methyl-2-pyrrolidone and texanol emitted from water based paints. Indoor Eniviron. 2010;13(1):39–54. https://doi.org/10.7879/siej.13.39.

    Article  Google Scholar 

  68. Onuki A, Saito I, Tada T, Fukuda M, Kurita M, Ogata A, et al. Trends in indoor air chemicals detected at high concentrations in newly built houses. Ann Rep Tokyo Metr Inst Pub Health. 2009;60:245–51. (in Japanese, English abstract).

    CAS  Google Scholar 

  69. Wang J, Li B, Yang Q, Yu W, Wang H, Norback D, et al. Odors and sensations of humidity and dryness in relation to sick building syndrome and home environment in Chongqing, China. PLoS One. 2013;8(8):e72385. https://doi.org/10.1371/journal.pone.0072385.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yasuaki Saijo .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Singapore Pte Ltd.

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Saijo, Y. (2020). Sick Building/House Syndrome. In: Kishi, R., Norbäck, D., Araki, A. (eds) Indoor Environmental Quality and Health Risk toward Healthier Environment for All. Current Topics in Environmental Health and Preventive Medicine. Springer, Singapore. https://doi.org/10.1007/978-981-32-9182-9_2

Download citation

  • DOI: https://doi.org/10.1007/978-981-32-9182-9_2

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-32-9181-2

  • Online ISBN: 978-981-32-9182-9

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics